CDA series pressure transducer are characterized by high quality and relatively low price in comparison to product merits.
Thanks to standard protective titanium nitride coating diaphragm, the pressure transducer offers high resistance to wearing providing necessary sensitivity at the same time. One-piece resistant stem of the pressure transducer makes it extremely resistant.
These transducer are the ideal standards to measure pressure in the plastic processing sector in the whole world. The precision of the pressure measurement goes hand in hand with accuracy ±0,5% of the max. ranges.
Pressure range | 0-100 to 0-1500 bar |
Total measurement error in % of maximum indication | ±0.5 |
Accuracy of indications in % | ±0.2 |
Range of indications | Unlimited |
Maximum overload of the rated value | 2x measuring range |
Membrane material | Titanium nitride 1.4541 |
Resistance of tensiometric sensor | 350 Ohm DMS |
Output signal | 3.33 mV/V |
Power Supply | 6-10 VDC |
Calibration point in % of the range | 80 |
Insulation resistance | 1000 MOhm at 50 VDC |
Maximum temp. at membrane | 410°C |
Max. temp. at electronic part | 85°C |
Max. allowed mounting torque | 1/2″-20UNF-2A = 5 Nm M18 x 1.5 = 10 Nm |
D1 | D2 | D3 | D4 | D5 | A | B | C | SW |
---|---|---|---|---|---|---|---|---|
M18 x 1.5 | 10 | 16 | 16 | 16 | 6 | 14 | 20 | 19 |
1/2-20UNF-2A | 7.8 | 10.5 | 10.5 | 12.5 | 5.6 | 10.8 | 17 | 17/19 |
Wybierz parametry czujnika jaki potrzebujesz.
Your order symbol:
CDAXX0 –XX–XXX–X